Infrared heating panels are a modern method of heating with low purchase costs, very low consumption, and cheap D45d and D57d electricity rates.  They are very easy to install and their operation is maintenance-free. Their main advantage is the direct transfer of heat to the heated space. Another big advantage is the possibility of precise regulation of each individual room.


Main advantages of infrared heating panels

Fast and clean installation - if the building is ready for electrical installation, it can be assumed that the installation of your heating system won't take more than one day.

Freedom of space, choose the placement - wall and ceiling installation of heating panels.

All you need is electricity - no gas connection, no flue routes, no room for complex equipment and a fuel depot. You can therefore use the space in the boiler room to store food or for other purposes.

No service required - FOUCZECH infrared heating is free of service, annual revisions and overhauls.

Modern design - unframed glass infrared panels look attractive in modern interiors and rustic rooms.

Clean air - infrared heating panels don't just heat, they also dry - helping prevent mold and saltpeter. This keeps buildings dry and permanently clean, extending their service life.

They prevent dust whirl and are suitable for allergy sufferers and asthmatics, they don't burden the environment and they create ideal conditions for human needs.

They ensure an ideal level of humidity. FOUCZECH heating panels are a Czech product for a lifetime. We make the heating panels exclusively from materials that come from EU countries.

Easy operation and smart home - The panels are thermostatically controlled in each room and are fully compatible when connected to any smart home system.

Quiet and easy operation - no dripping, water flow, banging or venting - heating panels are quiet, clean and maintenance-free.

100% thermal comfort - the system is based on the principle of radiant heat. Air circulation is reduced to a minimum, and heat is distributed evenly throughout the room.

High-quality infrared heating must meet the following requirements:

The heating surface must be glass.  Glass has the highest emissivity of infrared radiation. The glass must be completely smooth to avoid undesired convection. FOUCZECH uses safety toughened glass ESG.

Heating element.  It is most effective to have a printed circuit board applied to the glass. It consists of precious metals such as silver, tungsten, copper and others. Thanks to this technology, the performance of our panels is unchanged for decades, and they have an optimal panel temperature rise.

Insulation.  High-quality insulation of the back cover results in better heat generation on the glass, as well as reduced unwanted heating and air flow behind the panel (convection). Thanks to perfect insulation, our panels can also be placed on mildly flammable objects.

Surface temperture.  When switched on, the heating panel heats up to 100 °C, which is the ideal value for this type of heating. Touching a heated panel will not cause burns or skin damage. Thanks to the insulation, the back part of the heating panel is only slightly warm.

At lower operating temperatures the panel would not function properly and would approach the unwanted characteristics of convector heaters, while higher temperatures would negatively affect the user's comfort. First of all, the higher temperatures approach high-temperature radiators used for zone heating. The ideal surface temperature of the heating glass for heating apartment and office spaces is 100 °C.

You will find further details about the heating panels on the "Technical details" page.


Why choose heating panels from FOUCZECH?


Difficulty of implementing various types of heating

Overview of individual steps when acquiring heating

Heating panels from FOUCZECHHeating panels from FOUCZECH

  1. Project documentation for electrical wiring
  2. Supply and installation of energy-saving heating panels, including the development of a heating solution Heating system regulation
  3. Supply and installation of electrical wiring for the heating system
  4. Revision of electrical wiring

Gas boiler + floor heating Heating with gas boilere

  1. Project documentation for heating
  2. Project documentation for gas connector
  3. Project documentation for internal gas distribution
  4. Supply and installation of gas condensing boiler
  5. System board, manifold, pipes, valves, threaded joints, fittings
  6. Installation of floor heating
  7. Regulation of floor heating
  8. Supply and construction of a chimney - flue duct (chimney, flue)
  9. Supply and installation of gas connector
  10. Supply and installation of internal gas distribution pipes
  11. Revision of connector and internal gas pipes
  12. Revision of flue routes (chimney)
  13. Implementation of expansion joints, anhydrite screed laying
  14. Pressure tests
  15. Regular revisions and inspections of gas pipes and flue routes

Heat pump air/water + floor heatingHeating with a heat pump

  1. Project documentation for heating
  2. Project documentation for heat pump electrical wiring
  3. Supply and installation of electrical wiring for heat pump
  4. Supply and installation of air/water heat pump (these heat pumps have an electric boiler as a backup source)
  5. Heat pump regulation
  6. Regulation of floor heating
  7. Place for an outdoor unit and its attachment
  8. Place for an indoor unit and accumulator tank
  9. Revision test of the tightness of cooling circuits immediately after start-up
  10. Revision of electrical wiring
  11. System board, manifold, pipes, valves, threaded joints, fittings
  12. Installation of floor heating
  13. Pressure tests
  14. Insulation

Electric floor heatingFloor heating - modern heating

  1. Project documentation for electrical wiring
  2. Project documentation for heating
  3. Supply and installation of heating cables - heating films
  4. Regulation of floor heating
  5. Supply and installation of electrical wiring for the heating system
  6. Implementation of expansion joints, anhydrite screed laying
  7. Revision of electrical wiring

Electric convection heatersElectric convection heaters

  1. Project documentation for electrical wiring
  2. Supply and installation of electric convection heaters
  3. Supply and installation of wiring for electric convection heaters
  4. Extra regulation of convection heaters - recommended
  5. Revision of electrical wiring